MRR-RV205 · Advanced RV Systems Analysis & Quality Assurance
Technical diagnosis, system safety, applied calculations and quality assurance across major RV systems.
Open Semester I course →Study our full proposed 15-week RV systems semester—complete student lessons, supervised lab plans, assignments, self-checks, and a draft academic catalog—all directly on this page.
Begin with RV205 and progress through evidence-based diagnosis, integrated systems engineering, and advanced reliability research. Each semester proposes five academic credits. Twenty is a proposed evaluation total, not credits awarded by GRCC, RVTI or MRR.
Technical diagnosis, system safety, applied calculations and quality assurance across major RV systems.
Open Semester I course →Interpret imperfect evidence. Localize faults. Make defensible service decisions. 15 weeks of lessons, cases, supervised labs and research assignments.
Open Semester 2 course →Model complete systems. Verify component choices. Engineer safe, testable solutions. 15 weeks of lessons, cases, supervised labs and research assignments.
Open Semester 3 course →Investigate complex failures. Validate solutions. Defend technical and business decisions. 15 weeks of lessons, cases, supervised labs and research assignments.
Open Semester 4 course →Important: GRCC must approve courses and award its own credit. RVTI exams and technician certifications are separate, issued only through RVTI's authorized process. MRR is not yet an approved or accredited provider.
MRR-RV205 · Proposed second-year technical course with advanced capstone expectations. Study multi-step engineering calculations, evidence-based fault isolation, technical writing, controlled lab measurement, and system-level case analysis across all 15 weeks.
| Learning activity | Weekly | 15-week total |
|---|---|---|
| Classroom lecture | 3 hours | 45 hours |
| Supervised laboratory | 2 hours | 30 hours |
| Independent study | 10 hours | 150 hours |
| Total learning time | 15 hours | 225 hours |
Instructional hours are proposed and subject to institutional credit-hour evaluation and actual supervised delivery.
Recommended preparation: college algebra, introductory physical science, technical writing, unit conversions, and basic electrical safety. Students should be able to evaluate a data table, rearrange formulas, annotate a circuit diagram, cite manufacturer literature, and write a documented argument.
Scope: Sophomore-level technical analysis with selected junior-level research and capstone methods. GRCC primarily offers two-year associate programs; MRR-RV205 is not an assigned GRCC course number. Course instructors, lab facilities, credit transfer, and certification eligibility remain unapproved.
Required deliverables: source-annotated lab notebook, weekly calculations, twelve technical memos/problem sets, one midterm, a PDI portfolio, and an integrated capstone. Every quantitative answer must include assumptions, units, rounding, sources, and limitations.
Each unit combines analytical lectures, a solved problem, a controlled laboratory exercise, a technical research task, and a graded submission. The capstone requires an oral defense.
Each week, students must read applicable manufacturer service literature rather than invent universal component ratings. Use original documentation where available; inspect the publication date, product scope and safety notices. Course topic coverage has been mapped broadly to RVTI’s seven Level 1 systems, but this is an original MRR academic proposal—not RVTI’s licensed curriculum or an RVTI practice-certification exam.
RVTI training pathways ↗ · GRCC course-format and credit-hour policy ↗
PROFESSIONAL PRACTICE • FAILURE ANALYSIS • TECHNICAL WRITING • 3 h lecture · 2 h supervised lab · 10 h independent study
A repair diagnosis is a claim about causation. It is not established by how convincingly a technician describes a symptom. Distinguish the owner's reported history, direct observation, measured data, inference, and a confirmed defect. A strong service record names the measuring instrument, operating state, unit of measurement, relevant conditions, component identification and uncertainty. For example, 'battery low' is weak; '12.1 V measured at battery terminals after 30 minutes disconnected from shore power, ambient 20°C, state of charge not independently verified' is auditable. It is still not a battery-health test.
Use a structured risk model before technical testing. In failure mode and effects analysis (FMEA), severity, occurrence and detectability can each be assigned ordinal categories, but multiplying them into a risk-priority number does not make the result a physical probability. Document the rationale for ratings and prioritize high-severity hazards even when they are uncommon. Distinguish an unsafe condition from an inconvenience and specify whether work is suspended, deferred to a specialist, or continued within a limited authorization.
A causal argument must survive alternative explanations. An inoperative receptacle after rain is consistent with moisture intrusion, loss of supply, protective-device operation, an open conductor, or equipment failure. Replacing a converter without testing the relevant DC charging path is a category error. A professional communicates hypotheses as hypotheses; a written estimate should separate confirmed work from provisional diagnosis and indicate dependencies before quoting repairs.
A simulated service case rates water near a shore-power inlet as severity 5/5, occurrence 2/5, detectability 4/5. The descriptive priority index is 5×2×4 = 40. A cosmetic latch issue rated 2×5×4 = 40 has the SAME index but a very different hazard. Explain why severity-first escalation overrides a tie in the aggregate score.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A customer reports intermittent 120 V power after heavy rain. A previous repair ticket says “bad converter” and offers no voltage data. Prepare a one-page evidence map distinguishing observations, hypotheses, contraindicated tests, and qualified referral. No attempt to energize the affected system is permitted.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Using photographs, de-energized mockups, and fictional tickets, teams perform hazard triage, identify missing test conditions, and peer-review service notes. Deliver a signed observation log and a justified stop-work decision. No live-power exposure.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
Distinguish correlation from causation in a repair history. Provide one falsifiable test for each hypothesis that is safe within course scope.
Locate an actual OEM service notice or manual for a chosen RV component. Extract its revision date, applicability, limitations, and diagnostic prerequisites.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Prepare a 1,000–1,200-word technical memorandum: three competing hypotheses, a fault-tree sketch, FMEA with rating rationale, evidence hierarchy, customer-facing disclosure, and at least two appropriately cited technical references.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
MATERIALS • STRUCTURE • SYSTEMS ENGINEERING • 3 h lecture · 2 h supervised lab · 10 h independent study
An RV is a mobile, coupled system—not a house installed on a trailer. Road-induced vibration and torsion, thermal cycling, water exposure, and differing material expansion rates challenge joints, penetrations, sealants, and fasteners. A local defect can travel across interfaces: a roof penetration admits moisture; substrate stiffness decreases; attachment loads redistribute; subsequent vibration increases joint movement. Diagnosis should trace the failure chain rather than isolate the most visible stain.
Load-path reasoning starts with where force enters, which components transmit it, and where reactions are supported. In an idealized axial member, deformation scales as δ = FL/(AE), where F is force, L length, A cross-sectional area, and E elastic modulus. The expression is useful conceptually but not a license to certify RV structural components; real joints are anisotropic, fastener-dependent, and subject to combined loading. Explain why adhesives and composite laminates cannot be assessed solely from surface appearance.
Inspection sequences should maximize information while minimizing disturbance. Map body, chassis, electrical, LP, and water interfaces; distinguish a manufacturing identifier from a model designation; document attachments with dated, labeled photographs. A moisture meter reading can support a comparative survey but cannot independently establish trapped water quantity, source, or structural adequacy. Record baseline conditions, likely confounders, and what invasive work would require authorization.
Two axial members are the same length and material, but one has 50% more cross-sectional area. Under equal axial load, δ₂/δ₁ = A₁/A₂ = 1/1.5 ≈ 0.667. Discuss why an RV frame-to-body attachment cannot be validated from this simplified relationship alone.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A travel trailer shows staining at a ceiling seam and a cabinet door that intermittently binds after towing. Construct a potential causal pathway linking water, structural deformation, and thermal movement. State which findings require structural referral.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
On an inert RV cutaway or diagram, map force paths, identify different material interfaces, and prepare a nondestructive inspection protocol. Compare two moisture-indicator readings without making unsupported claims about water content.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
Explain the limitations of δ = FL/(AE) for laminated walls and bolted attachments. List at least four assumptions violated in field conditions.
Select two manufacturer body-care or sealant documents and compare inspection interval language without generalizing one OEM’s guidance to all RVs.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Develop an annotated system-interface map with ≥20 components and eight interdependencies, a 900-word mechanical justification, and a prioritized noninvasive inspection sequence.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
APPLIED CIRCUITS • ALGEBRA • MEASUREMENT • 3 h lecture · 2 h supervised lab · 10 h independent study
A 12 V nominal RV distribution network is a collection of sources, impedances, loads, switches, connectors and protective devices. Kirchhoff’s current law conserves current at nodes; Kirchhoff’s voltage law sums potential changes around a loop. Under steady DC conditions, V = IR and P = VI provide first-order estimates. A successful analysis distinguishes source voltage, voltage across the load, and losses in the round-trip path. Nominal system voltage is not a guarantee that the bus remains exactly at 12.0 V under all conditions.
Conductor resistance depends on material resistivity, length, cross-sectional area and temperature. Both outbound and return conductors contribute to circuit voltage drop. If a connector is corroded, a high-resistance joint may dominate loss even with an adequately sized cable. Measure voltage drop across each section under an appropriately controlled load, rather than inferring continuity from an unloaded meter reading. A circuit can show full voltage at zero load and still be incapable of supplying operating current.
A fuse or circuit breaker protects wiring and mitigates faults within the protection scheme; its rating is not merely selected to match the appliance’s normal operating current. Correct selection depends on conductor ampacity, installation conditions, manufacturer instructions, available fault current, protective-device characteristics and applicable rules. Do not infer compliance from a quick Ohm’s law calculation. Field selection and modifications are outside the scope of this classroom trainer.
An isolated 12.6 V trainer supplies 12 A through a total round-trip conductor length of 8.0 m at assumed resistance 0.0063 Ω/m. R = 0.0504 Ω; ΔV = IR = 0.6048 V; load-terminal voltage ≈ 12.00 V; resistive loss = I²R ≈ 7.26 W. The drop is 4.80% of 12.6 V. Repeat for twice the current and discuss heat scaling.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A slide-control trainer shows 12.7 V unloaded at its input but falls below 11.7 V when a 10 A simulated load engages. Model the likely series resistance; design an instrumented low-voltage test that localizes rather than guesses at the fault.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
On an instructor-inspected, fused, current-limited trainer ≤12 V, measure node voltage, source current and conductor drop with two load conditions. Compare predicted and observed values; include uncertainty and a circuit schematic.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
Compute what happens to conductor dissipation if current increases from 12 A to 18 A with constant resistance. Explain why the ratio is (18/12)² = 2.25 rather than 1.5.
Use a component manufacturer’s electrical diagram to distinguish normal current draw, overcurrent protection, and permissible voltage range.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Submit a quantitative lab report (1,200 words max), circuit schematic, raw data table, uncertainty budget, voltage-drop plot, and diagnosis justified against at least two fault hypotheses.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
INSTRUMENTATION • STATISTICAL REASONING • 3 h lecture · 2 h supervised lab · 10 h independent study
Troubleshooting is an experimental-design problem. Select the next test for the information it can provide, not because it is easy or familiar. When several hypotheses predict the same reading, that reading is weak evidence. Compare predicted voltage signatures for a degraded supply, intermittent ground return, faulty switch, and variable load. For each experiment define controlled variables, measuring location, operating state, and stop-work conditions before touching the trainer.
A digital multimeter’s reading is not identical to the true quantity. Accuracy specifications often combine a percentage of reading and a number of display counts. Contact resistance, lead placement, temperature and transient load behavior may produce effects larger than nominal meter error. Estimate measurement uncertainty from the stated instrument specification and repeated readings. Use significant figures honestly: a display showing 12.345 V does not guarantee 1 mV accuracy.
Compare open-circuit voltage and loaded voltage to infer an apparent series resistance using R_app = (V_oc – V_load)/I, while noting that source state, dynamic behavior, wiring and connector losses are combined. R_app is not automatically the battery’s internal resistance. A systematic fault tree identifies what additional measurement would separate internal source degradation from an external connector problem.
A training supply reads 12.70 V with no load and 11.95 V at 10.0 A. Apparent series resistance is (12.70–11.95)/10.0 = 0.075 Ω. If current varies by ±0.3 A and the readings drift ±0.05 V, identify why a single estimate should not be treated as an exact component value.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A simulator exhibits intermittent loss of voltage during a “motor-start” load. There are three candidates: shared return, supply droop or corroded simulated terminal. Design a three-measurement sequence that distinguishes them.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Students collect replicated current/voltage observations on an isolated DC fault-insertion panel. Plot measurements and calculate mean, range and apparent series resistance; document any inconclusive results.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
Given a meter specification ±(0.5% of reading + 2 counts) at 0.01 V resolution, estimate maximum stated error at 12.00 V: ±(0.060 + 0.020) V = ±0.080 V. Explain how that affects a claimed 0.05 V difference.
Read a meter manual for input category limits and accuracy. Describe why a current-limited training source still does not authorize energized AC measurements.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Produce a test-plan matrix with four hypotheses, predictions, safety gates, measured outcomes, uncertainty discussion and a conclusion that explicitly states what remains unknown.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
POWER SYSTEMS • HUMAN FACTORS • SAFETY • 3 h lecture · 2 h supervised lab · 10 h independent study
RV AC power introduces distinct conductors and functions: ungrounded (hot) conductors carry supply potential, neutral provides a designed current return where applicable, and equipment grounding conductors facilitate fault clearing. They are not interchangeable. Protective components such as overcurrent breakers, GFCI protection, and transfer equipment address different failure modes. A breaker is not a substitute for personnel shock protection, and a GFCI does not prove the absence of every hazard.
Nominal appliance loading begins with P ≈ VI for resistive or near-unity-power-factor cases. For loads with reactive components, apparent power S = VI is measured in volt-amperes and real power P = VI cosφ. Starting inrush, duty cycles, branch-circuit configuration and nameplate requirements complicate simplistic addition of rated watts. Shore connection and bonding arrangements require application of the relevant currently adopted standards and qualified review; this course does not provide installation authorization.
Diagnostic reasoning must be bounded by exposure control. Students should interpret isolated schematics, review photographs and evaluate outcomes provided by an instructor—not probe live shore-power receptacles or bypass GFCI, bonding or transfer equipment. A recurring trip may indicate leakage, overload, damaged wiring, equipment defects or an inappropriate circuit arrangement. Responsible analysis records symptom timing, load conditions and device identification before escalation.
An illustrative AC load operates at 120 V and draws 10 A at power factor 0.85. Apparent power is 1,200 VA; real power is 1,020 W. Treating it as a 1,200 W resistive load misrepresents consumption. Explain why this does not by itself determine circuit compliance.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A customer reports a GFCI trip whenever an RV is connected to shore power. Given an instructor-provided one-line diagram and hypothetical test data, categorize plausible leakage/connection hypotheses without proposing a bypass.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
With no live AC: annotate one-line diagrams, identify protective boundaries using component mockups, and develop a lockout/referral checklist. The instructor demonstrates safe isolation concepts without student energized work.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
Compute S and P for 120 V, 14 A, power factor 0.92: S = 1,680 VA and P ≈ 1,546 W. Explain why generator selection must also consider starting loads.
Identify the applicable manufacturer and code-reference documents for a specific installed AC component; do not cite a general electrical blog as a substitute.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Write a technical hazard review comparing branch overcurrent protection, GFCI function and grounding. Include a power-budget calculation and a decision tree for professional escalation.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
ENERGY SYSTEMS • POWER ELECTRONICS • 3 h lecture · 2 h supervised lab · 10 h independent study
Ampere-hours measure charge delivered at a defined test regime, not energy independently of voltage. An energy approximation is E_nom ≈ V_nom × capacity_Ah. Battery chemistry, discharge rate, temperature, cell balancing, state of health and BMS operating limits affect usable capacity. A system design should separate nameplate energy, permitted usable energy, conversion losses, and reserve margin. Do not assume that voltage alone determines lithium battery state of charge.
A converter, charger, inverter and solar charge controller have different directional roles in the energy chain. The inverter’s AC output power requires greater DC input power because conversion efficiency is less than unity; standby consumption continues even when the primary load is off. Solar array nameplate watts are test-condition ratings, not daily guaranteed production. A daily yield model combines array size, equivalent sun-hours, orientation/temperature losses, controller losses and shading uncertainty. The model must be stress-tested over poor-weather days, not just averaged sunshine.
Thermal and protective constraints matter. Power dissipated as heat is P_loss = P_in – P_out. High battery discharge currents can trigger a BMS, overcurrent protection or inverter shutdown even when an advertised watt-hour capacity appears sufficient. System troubleshooting should consider transient starting loads and conductor voltage drop, never rely on bypassing protective devices.
A nominal 12.8 V, 100 Ah battery stores about 1,280 Wh. At an assumed 80% usable fraction and 90% inverter efficiency, AC-deliverable energy ≈ 921.6 Wh. An 80 W continuous load would run about 11.5 h in this idealized model, excluding inverter idle draw and other loads.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A camper reports that a 2,000 W inverter shuts down during hair-dryer startup despite a fully charged 300 Ah battery. Propose evidence distinguishing surge/current limit, voltage sag, BMS cutoff and wiring loss; do not recommend bypassing the BMS.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Build a spreadsheet energy model from instructor-provided nameplates and weather scenarios. Change assumed sun-hours and inverter efficiency; quantify sensitivity and document uncertainty.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
A 300 W array produces during 3.5 equivalent sun-hours/day with combined yield factor 0.70. Estimated daily energy is 300×3.5×0.70 = 735 Wh. Compare with a 1,200 Wh/day demand and quantify deficit.
Review actual battery/BMS and inverter documentation for continuous output, surge rating, temperature restrictions and protection behavior.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Submit a seven-day energy audit and design memo showing daily Wh consumption, discharge reserve, converter losses, peak-W vs energy distinctions, and at least two adverse-weather scenarios.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
FLUID SYSTEMS • PRESSURE AND FLOW • 3 h lecture · 2 h supervised lab · 10 h independent study
Water delivery in an RV is a small hydraulic network with storage, a pump or shore supply, check valves, distribution piping, fixtures and controls. Pressure is a potential for flow, not a measure of how many gallons actually move. A gauge can show substantial static pressure even when a clogged strainer or kinked line severely restricts flow. Distinguish a supply-side restriction from a downstream valve fault by proposing observations that change differently under each hypothesis.
Use Q = V/t for volumetric flow and the continuity relationship Q = Av for steady incompressible flow at a point, while acknowledging that pumps cycle and transient demand is not steady. Pressure losses depend on tubing diameter, length, bends and fittings. For laminar idealized flow, Poiseuille’s relation predicts strong radius sensitivity, but RV piping commonly operates outside those simplifying assumptions. Avoid inventing a pressure-loss number without the necessary piping geometry and fluid conditions.
Health and contamination concerns are part of technical competence. Evidence of a backflow event, unknown chemical exposure or cross-connection requires appropriate escalation. Students may work with clean water and isolated transparent trainers but not introduce chemicals or open contaminated wastewater components. Record the boundary between a plumbing diagnostic concept and a manufacturer-approved sanitization procedure.
A faucet provides 3.5 gal/min for 2.0 min: V = Qt = 7.0 gal. A 30-gal freshwater tank would contain 23 gal afterward only if initially full, the flow is constant, there are no other uses and the pump draws solely from that tank.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
Two fixtures exhibit reduced flow only when operated together; the pump cycles rapidly at a single fixture. Compare hypotheses involving pump performance, aerator restrictions, trapped air and tank draw.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Use a clear-tube low-pressure water demonstrator with no chemicals or utility interconnection. Measure tank draw, simulated pressure indication and fixture flow at two controlled settings.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
If a trainer supplies 4.0 L/min for 75 s, determine liters delivered: 4.0×(75/60) = 5.0 L. Express assumptions for a continuously varying pump.
Use an OEM pump performance curve and compare rated free-flow to operation under a specified pressure.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Create a hydraulic system block diagram, calculate three timed-flow scenarios, interpret a diagnostic data sheet, and write a customer-facing noninvasive assessment memo.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
SANITATION • MASS BALANCE • PROCEDURES • 3 h lecture · 2 h supervised lab · 10 h independent study
Fresh, grey and black tanks have distinct functions and hazards. Tank sensors may report unreliable levels when fouled, so a displayed percentage should not be treated as precise inventory. Wastewater introduces biological exposure risks; open drains, tank vents and sewage connections are not appropriate for introductory student handling. An evidence-based training exercise can use isolated diagrams and clean-water demonstration units to teach mass balance without exposing students to contaminated media.
Mass balance can be written as accumulation = inflow – outflow over the analysis interval. When a trailer carries additional water, its total weight increases and remaining cargo capacity decreases. For water, a common approximation is 8.34 lb/US gal at ordinary conditions. Distribution among tanks matters because it shifts axle and tongue reactions. A tank-level change also has dynamic consequences during travel, including slosh and transient loads, even when the total mass remains constant.
Winterization is a system-level design problem: identify every water-holding component, bypass and low point; consult the specific manufacturer instructions; define inspection verification and records. A generic checklist can overlook an icemaker, tankless water-heater path, washer or external shower. Do not prescribe a single antifreeze or chemical routine across all models. Course work emphasizes document traceability and planning, not unapproved chemical operations.
A 35-gallon tank of water adds approximately 35×8.34 = 291.9 lb. If a trailer has only 500 lb of remaining payload capacity before filling, the theoretical remainder falls to about 208 lb, assuming no other cargo changes.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A customer reports freeze damage after a prior winterization; the invoice lists “winterized” with no appliance inventory or verification details. Analyze how incomplete system mapping prevents a defensible warranty conclusion.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Trace a mock RV water system from diagrams and flag hidden branch lines, pump bypasses, heaters and low points. Estimate mass effects for alternative fill states. No wastewater handling.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
Translate a 22-gal grey tank rise into estimated water weight (22×8.34 ≈ 183.5 lb). Explain why tank-monitor readings alone may not support that precision.
Compare two manufacturer winterization instructions for different water-heater configurations; identify non-transferable steps.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Prepare a model-specific winterization risk register with ≥12 checkpoints, evidence type for each, uncertainty notes, and a post-procedure verification plan tied to actual OEM sources.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
FUEL SYSTEMS • COMBUSTION • SAFETY ENGINEERING • 3 h lecture · 2 h supervised lab · 10 h independent study
An RV LP-gas installation includes a fuel container, vaporization process, pressure regulation, distribution, appliance controls and exhaust pathways. Pressure and phase behavior depend on temperature and mixture; a cylinder is not simply a constant-pressure gas reservoir. A device that burns fuel indoors introduces risks associated with incomplete combustion, inadequate ventilation, faulty venting and carbon monoxide. A general-purpose electronic detector is not a substitute for correct installation and professional evaluation.
Energy analysis can estimate theoretical fuel-use duration from the chemical energy content of fuel divided by burner input, but it does not establish appliance efficiency or safe operating time. For an illustrative 20 lb propane quantity, multiplying by roughly 21,500 Btu/lb yields approximately 430,000 Btu of chemical energy. At an input rating of 24,000 Btu/h, simple arithmetic yields about 17.9 hours of burner-on time; actual performance depends on duty cycle, available vaporization, load, regulation and other consumers.
Students must not manipulate LP regulators, leak-test pressurized fuel systems, defeat flame controls, light burners, adjust combustion or conduct live appliance servicing. In this course, hazard recognition is taught through simulated schematics, incident narratives and inert parts. The right response to suspected leakage, damaged venting or CO symptoms is immediate appropriate safety action and qualified referral under a documented emergency plan.
20 lb × 21,500 Btu/lb = 430,000 Btu. 430,000 Btu ÷ 24,000 Btu/h ≈ 17.9 h at continuously rated input. This is a simplified capacity estimate, not a performance or safety certification.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
An occupant reports headache and a CO alarm while a furnace is operating. Build an incident-response communication and referral memo; do not propose a technician experiment involving operation of the appliance.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Compare inert regulators, shutoff images and venting schematics; identify hazardous assumptions in a mock service ticket. Grade risk recognition, not system adjustment.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
If two appliances have rated inputs of 24,000 and 8,000 Btu/h, calculate combined input and the idealized runtime for 430,000 Btu: 32,000 Btu/h, ≈13.4 h. State three reasons this is not a field prediction.
Find current OEM operating limitations for an actual LP appliance; specify its model and the provenance of each instruction.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Compose a combustion hazard briefing that distinguishes CO, oxygen depletion, ventilation and pressure regulation; include an energy calculation and an emergency escalation decision tree.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
THERMODYNAMICS • HEAT TRANSFER • 3 h lecture · 2 h supervised lab · 10 h independent study
Air-conditioning capacity and electrical input are not interchangeable. A rooftop unit may remove heat at a rate expressed in Btu/h while consuming electrical power in watts. The coefficient of performance (COP) is useful when cooling heat transfer and input power use consistent energy/time units. In a simplified vapor-compression cycle, the compressor raises refrigerant pressure, the condenser rejects heat, the expansion device reduces pressure, and the evaporator absorbs indoor heat. Real COP varies with outdoor temperature, airflow, load, condition and equipment design.
Thermal diagnosis requires appropriate boundary conditions. An interior air temperature is not enough to identify low refrigerant, dirty coils, undersized equipment, recirculation, poor electrical supply or excessive envelope heat gain. A proper analytic record includes ambient dry-bulb conditions, return and supply temperatures, fan state, load history and the OEM's approved measurement method. Do not diagnose a sealed refrigeration circuit from a single temperature difference.
RV absorption refrigerators and gas appliances follow fundamentally different energy-conversion and safety processes than compressor-driven refrigeration. A technician must identify the appliance type before applying a mental model. Because these devices may involve LP gas, AC power, sealed refrigerant systems and combustion venting, this course restricts direct student work to diagrams, inert demonstrations and manufacturer-supplied datasets.
13,500 Btu/h ÷ 3.412 ≈ 3,956 W of cooling. If illustrative COP = 2.5, required electric input ≈ 1,582 W. The result is a model estimate; actual starting current, fan load, test conditions and equipment data control field decisions.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
An RV AC runs but does not cool adequately on a hot afternoon. The owner suspects refrigerant loss. Given temperature, shading, fan and power data, rank at least four hypotheses and identify noninvasive tests.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Analyze time-series thermal measurements from instructor-provided data; graph indoor temperature response and explain why correlation with compressor cycling does not prove a refrigerant defect.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
An idealized unit removes 9,000 Btu/h while consuming 1,100 W. Cooling rate ≈2,638 W; COP ≈2.40. Explain how ambient temperature and airflow affect interpretation.
Locate OEM performance and installation documents for a specific RV rooftop AC; distinguish performance tables from marketing capacity ratings.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Prepare a comparative engineering report on compressor refrigeration, absorption refrigeration and forced-air heating, with energy-flow diagrams and a climate/load sensitivity analysis.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
AC GENERATION • ENERGY CONVERSION • 3 h lecture · 2 h supervised lab · 10 h independent study
A generator provides electrical power by converting fuel energy into shaft work and then into electrical output; the system involves prime mover control, voltage/frequency regulation, cooling, exhaust and protection. Rated output depends on conditions, and appliance starting currents can exceed steady-state demands. A list of nameplate watts may miss motor starting peaks, battery charging loads, simultaneous-operation patterns and duty cycle.
Power source selection involves a transfer mechanism and the prevention of unintended backfeed. Incorrect interconnection can expose users and utility personnel to severe hazards. This course therefore teaches source-selection diagrams only: no generator starting, fuel handling, exhaust work, source-paralleling, or electrical modification. Evaluate proposed configurations against the specific equipment instructions and appropriate professional review.
Effective fault isolation distinguishes a generator that does not start from one that starts but fails to deliver usable power, and from a case where load-side distribution does not receive power. Each failure class implies different evidence. A good report identifies preconditions, nameplate data, historical patterns, fault indications and whether protective devices have operated; it does not promote indiscriminate resetting.
A nominal 3,600 W generator supplies simulated concurrent loads of 1,600 W and 900 W: 2,500 W total, about 69.4% of rating. The arithmetic leaves 1,100 W nominal headroom before considering starting surge, altitude, temperature, power factor and equipment restrictions.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
Shore power works, the generator starts, but several AC loads remain inactive. Interpret an instructor-provided distribution one-line diagram and identify what qualified diagnostic data would discriminate transfer-device versus downstream faults.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Design a load-scheduling spreadsheet and annotate a de-energized source-selection diagram. Evaluate a simulated overload event using data only; no live generator operation.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
A 3,600 W rating is compared to a 2,500 W load: 69.4% utilization. Add a 1,500 W motor starting event and explain why transient capability cannot be inferred from continuous rating alone.
Use a genuine generator nameplate/manual to distinguish rated, surge, derated and altitude-related constraints.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Submit a generator systems analysis with capacity scenarios, expected transfer states, hazard register and evidence-based explanation of three alternate causes of power loss.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
BUILDING PHYSICS • MATERIALS • 3 h lecture · 2 h supervised lab · 10 h independent study
An RV enclosure faces wind-driven rain, capillary action, pressure differences, thermal movement, vapor diffusion and mechanical vibration. A roof stain is not a uniquely identifying signature of the entry point. Water can travel along framing or wiring before appearing at a ceiling seam. Diagnostic reasoning therefore separates entry, transport path, accumulation and visible manifestation. Replacing all sealant without identifying the governing failure mechanism may conceal rather than resolve a problem.
Materials have different thermal expansion, stiffness, adhesion and moisture behavior. Sealant selection depends on compatibility with the actual roof membrane, substrate and manufacturer maintenance instructions. Adhesive bond performance is affected by contamination, surface energy, cure conditions and joint geometry. A generic statement that a product is 'RV safe' cannot substitute for the OEM’s approved material specification.
Quantitative exposure estimates are useful for appreciating scale but should never be mislabeled as actual water intrusion. Rainfall depth multiplied by exposed area gives incident water volume; it does not say what fraction crosses a breach. Photographs must be labeled with location and scale, moisture instrument readings must identify conditions, and inspection reports should state which regions were inaccessible and which conclusions remain provisional.
For an idealized horizontal 100 ft² roof receiving 0.50 in rain: V = 100 ft² × (0.5/12) ft × 7.4805 gal/ft³ ≈ 31.2 gal incident rain. This is NOT 31.2 gallons leaked into the RV; runoff and infiltration fraction are unknown.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A customer sees dampness at a rear closet only during highway travel after rain. Compare wind-driven ingress, roof penetration failure, sidewall interface and condensation hypotheses.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Inspect calibrated photographs and benign mock joints; assemble a defect matrix documenting orientation, suspected pathway, confidence and OEM document needs. No climbing or roof access.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
Double the assumed rainfall depth in the worked example: incident volume doubles to ~62.3 gal. Explain why the relationship between rain depth and interior damage need not be linear.
Compare two actual OEM roof-maintenance bulletins for inspection interval and sealant compatibility; cite model applicability.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Prepare a roof-system forensic memo with a scaled leak-path diagram, compatibility decision chart, evidence quality analysis and staged inspection plan.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
STATICS • VEHICLE SYSTEMS • 3 h lecture · 2 h supervised lab · 10 h independent study
A trailer’s rated limits operate at several levels: gross vehicle weight rating (GVWR), gross axle weight ratings (GAWR), component ratings and tow-vehicle limitations. Weight distribution is not captured by a single 'dry weight' advertisement. Static force equilibrium requires the sum of support reactions to equal total weight, but individual axle and tongue reactions depend on cargo location and geometry. A combined axle scale measurement cannot reveal whether one axle is overloaded.
For a simplified static beam, moments about a support location relate load magnitudes and distances. Cargo moved behind the axle group can reduce tongue reaction while raising or redistributing axle forces; this does not imply safe handling. Dynamic factors such as braking, road input and sway are not resolved by a static worksheet. Document the origin and date of every rating and scale reading before drawing a compliance conclusion.
Brakes, bearings, tires and suspension components are safety critical. Proper inspection requires manufacturer procedures, appropriate lifting and support, calibrated tools, and trained personnel. The course does not authorize lifting a trailer or servicing brakes/bearings. Case studies use photographs, component data and simulated tickets to practice identifying when a vehicle must be removed from service or professionally inspected.
Illustrative trailer: GVWR 7,600 lb; measured combined axle reaction 6,500 lb; measured tongue reaction 800 lb. Estimated gross trailer weight = 7,300 lb, leaving 300 lb below GVWR. This does NOT prove compliance with any individual GAWR, tire rating, hitch rating or tow-vehicle limit.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A loaded trailer has an acceptable total scale weight but abnormal tire heating on one side. Explain why aggregate GVWR compliance is insufficient and describe qualified next steps.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Interpret synthetic individual-axle and tongue scale tickets; reconcile totals, identify missing ratings and annotate a free-body diagram. No jacking, towing or mechanical work.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
Using the illustrative 7,300 lb total and 7,600 lb GVWR, calculate 3.95% nominal remaining GVWR margin. Discuss why a margin near zero must be interpreted cautiously.
Identify vehicle manufacturer labels and OEM documentation needed to verify GAWR, GVWR, tire loading and hitch limitations.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Complete a towing-readiness analysis with rating-source table, payload scenarios, two support-reaction calculations and a risk communication letter.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
QUALITY ASSURANCE • INSPECTION METHODS • COMMUNICATION • 3 h lecture · 2 h supervised lab · 10 h independent study
Pre-delivery inspection is a quality-assurance process designed to establish the observable condition of an RV at a defined moment, not a promise that every component is defect-free. A useful procedure specifies prerequisites, test method, measurement, acceptance criterion, evidence to retain and disposition when criteria are not met. An unobserved test cannot be reported as 'passed'. Distinguish 'not tested', 'not applicable', 'inconclusive' and 'failed'.
Inspection quality can be assessed with the logic of diagnostic tests. A false negative occurs when the process fails to detect a condition that exists; a false positive occurs when it flags a problem incorrectly. Increasing inspection coverage often improves detection but requires time, skills and access. A worksheet should prioritize life-safety hazards, document component-specific instructions and include reinspection after corrective work. The institution must determine which checks require certified staff.
The final customer document translates technical evidence into an informed decision. It should name confirmed findings, reasons for referral, unresolved risk, test exclusions, recommended next steps and authorization required. Ethical language avoids claims like 'everything tested good' when only a partial systems survey occurred. Customer education must preserve the distinction between normal operation, observed anomaly, and unverified expectation.
In a simulated set of 100 known inspection cases, an inspection flags 18 of 20 actual defects and flags 8 of 80 acceptable cases. Sensitivity = 18/20 = 90%; specificity = 72/80 = 90%. Explain why simulated performance does not establish actual field accuracy.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
A PDI form lists all items “passed,” yet there is no record of the water system operating and shore power was unavailable. Rewrite the report with valid status language and a customer follow-up plan.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Perform a non-invasive PDI on an inert lab rig or simulated dataset. Peer-review evidence attachments and classify each observation using a standardized disposition code.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
Given 18 true positives, 2 false negatives, 8 false positives, and 72 true negatives, compute sensitivity, specificity and positive predictive value (18/26 ≈ 69.2%). Interpret the base-rate effect.
Compare a manufacturer PDI checklist with a generic template and justify additional model-specific checks.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Submit a model-specific inspection plan, completed simulated inspection, evidence index, defect-priority log and a two-minute oral customer briefing scored against a communication rubric.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
SYNTHESIS • APPLIED EVIDENCE • PROFESSIONAL COMPETENCY • 3 h lecture · 2 h supervised lab · 10 h independent study
Advanced technical practice integrates evidence across subsystem boundaries. A low-voltage event may affect a slide controller, water pump, thermostat and power transfer diagnostics; visible correlation across components may point to a shared supply, common return, protective device or operating condition. A capstone should avoid assuming a single root cause merely because the symptoms began together. Each proposed test must specify what distinct results would mean for competing hypotheses.
A strong capstone report is reproducible. Include the complaint history, system architecture, measured and assumed quantities, instrument condition, calculation work, source limitations, fault-tree revision history and final disposition. Distinguish a confirmed root cause from a most-likely explanation when the approved lab cannot reproduce a field failure. Where evidence is insufficient, a qualified referral with a focused test plan is a legitimate and professionally responsible outcome.
The oral defense is not a memory contest. Students must explain why their chosen test came before a different test, quantify the significance of a finding, evaluate safety boundaries, and respond to a challenge involving alternative interpretations. Technical competence includes the willingness to revise a conclusion when new evidence contradicts it.
An isolated DC trainer reads 12.6 V unloaded and 11.8 V with an 8 A simulated motor load. Apparent series resistance = (12.6–11.8)/8 = 0.10 Ω. If the 12 V pump and control panel share the same return, propose a discriminating voltage-drop test before condemning either load.
Present derivation, units, sensitivity and the limits of every result. Values in illustrative problems are not equipment specifications.
Simulated RV: the pump stops intermittently when a slide is commanded, the charging system reports normal status, and a customer reports prior rain exposure. Investigate shared ground, protective device, supply sag, harness damage and observational bias using a provided evidence packet.
Discussion protocol: State observed facts; formulate ≥3 competing hypotheses; identify one discriminating test for each; rank severity-first risks; report what cannot be inferred from the evidence.
Teams defend an instrumented low-voltage diagnostic demonstration on a fused, current-limited trainer. The instructor evaluates safe setup, measurement repeatability, hypothesis testing, interpretation and documentation.
Lab authorization gate: instructor-approved equipment, verified isolation or simulator status, documented limits, and stop-work authority. Work on energized shore power, LP gas, generators, elevated roofs, or unstable trailers is excluded from unsupervised student activity.
A final answer must present at least one hypothesis disproved by test evidence and one unresolved issue with an ethical customer communication recommendation.
Cite at least four manufacturer/standards-level documents and identify which guidance is model-specific rather than universally applicable.
Identify author or issuing organization, revision/date, model applicability, relevant pages and conflicting assumptions. Explain what a source does not establish.
| Work | Hours | Required evidence |
|---|---|---|
| Technical reading and annotation | 3 | Source-annotated reading notes |
| Quantitative exercise and assumptions | 2 | Calculation sheet, units and sensitivity |
| Diagnostic case analysis | 2 | Evidence table and alternatives |
| Technical writing / research memo | 2 | Formal report with sources |
| Lab briefing and reflection | 1 | Safety checklist and corrections |
Submit a capstone technical dossier (2,000–2,500 words plus appendices), complete raw data, model diagrams, three computed analyses, a defensible fault tree, risk disposition, and a ten-minute oral defense.
Rubric (100 points): technical reasoning 30; quantitative accuracy and units 25; evidence quality and source traceability 20; safety/limitations 15; communication and formatting 10. Mandatory critical safety criterion: unsafe procedures or unacknowledged severe hazards require remediation regardless of numeric total.
Unlike the introductory knowledge checks elsewhere on MRR University, these applied items require quantitative justification, assumptions, and a written defense. Solutions are provided for self-study, not as secure summative examination keys.
Problem: An isolated trainer has 12.7 V open-circuit and 11.9 V under 8 A. Calculate apparent series resistance. If the drop measurement itself has ±0.08 V uncertainty, estimate the resulting resistance uncertainty assuming exact current; identify a confounder.
Study solution: R_app = (12.7 − 11.9)/8 = 0.10 Ω. From voltage uncertainty alone, approximate resistance uncertainty is ±0.08/8 = ±0.01 Ω. Actual uncertainty also includes current error, contact and lead resistance, temperature and source dynamics.
Instructor expectation: Show steps, units, caveats, and one competing explanation.
Problem: Daily AC load is 900 Wh, inverter efficiency 0.88, 12.8 V 200 Ah battery, 80% nominal usable fraction. Ignoring other losses, estimate how many no-charge days the battery sustains the load, and name two reasons the estimate is optimistic.
Study solution: Estimated usable DC energy = 12.8×200×0.80 = 2,048 Wh. AC-deliverable energy = 2,048×0.88 ≈ 1,802 Wh. ≈2.00 days at 900 Wh/day. Inverter standby draw, temperature, battery aging, BMS limit and transient overloads can reduce runtime.
Instructor expectation: Show steps, units, caveats, and one competing explanation.
Problem: An idealized cooling system transfers 10,200 Btu/h while consuming 1.20 kW. Calculate an approximate COP, then explain why this is not a diagnostic confirmation of refrigerant condition.
Study solution: 10,200 Btu/h ÷ 3.412 ≈ 2,989 W cooling. COP ≈2,989/1,200 = 2.49. COP is conditional on load, ambient state, airflow and measurement accuracy; it does not identify a particular sealed-circuit defect.
Instructor expectation: Show steps, units, caveats, and one competing explanation.
Problem: A trailer is rated at GVWR 8,000 lb. Combined axle scale = 6,950 lb and tongue scale = 700 lb. Calculate estimated gross weight and remaining GVWR margin. What cannot be certified?
Study solution: Gross ≈7,650 lb; remaining GVWR ≈350 lb (4.38%). Combined figures do not verify per-axle GAWR, tire limits, hitch/tow-vehicle ratings, scale conditions or safe dynamic handling.
Instructor expectation: Show steps, units, caveats, and one competing explanation.
Problem: A simulated PDI process finds 42 true positives, misses 8 defects, flags 12 nondefects and correctly clears 138 items. Compute sensitivity, specificity and positive predictive value; identify a customer-reporting caveat.
Study solution: Sensitivity =42/50=84%; specificity =138/150=92%; positive predictive value =42/54≈77.8%. Results depend on the simulated sample and prevalence; they do not establish accuracy for an actual RV model or guarantee a fully defect-free vehicle.
Instructor expectation: Show steps, units, caveats, and one competing explanation.
| Assessment | Weight | Evidence |
|---|---|---|
| Analytical problem sets / technical memoranda (12 graded) | 20% | Calculations, uncertainty, fault-tree reasoning and primary-source citations |
| Supervised lab portfolios (15 evidence logs) | 25% | Recorded measurements, diagrams, hypothesis tests, repeatability and safety gates |
| Midterm applied analysis (Weeks 1–7) | 15% | Multi-step technical problems, structured responses and critical hazard analysis |
| Final synthesis examination (Weeks 8–15) | 20% | Integrated systems analysis, quantitative cases and evidence critique |
| PDI and diagnostic capstone + oral defense | 20% | Reproducible technical dossier, seven-system coverage, oral defense |
Proposed performance threshold: at least 75% overall, 70% on each exam, and PASS on every critical safety gate. Analytical grading uses evidence, method, and defensible uncertainty—not memorization alone. These are draft institutional standards, not an authorized grading or credential system.
Written midterm/final exams and faculty keys are held in a separate instructor review packet. The public self-checks above are not certification tests.
| Term | Working definition |
|---|---|
| Inspection | An evidence-based observation and limited check against defined criteria. |
| Diagnosis | A reasoned determination of fault cause, supported by appropriate testing. |
| Scope of work | The customer-authorized boundaries of the service. |
| Safety-critical finding | A condition that requires stop-work, isolation or qualified escalation. |
| Evidence | A labeled image, measurement, record, or observed result with context. |
| PDI | Pre-delivery inspection: structured verification of RV readiness and documented exceptions. |
Voluntary, original Christian vocational reflections on truthfulness, stewardship, service, responsible work, and accurate interpretation of Scripture. These reflections are noncredit and are not used to evaluate technical ability or academic achievement. They are not affiliated with or endorsed by John MacArthur, Grace Christian University, or other institutions.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
What does this passage teach about truthful responsibility, care for one’s neighbor, humility, diligence or mercy? How could those convictions shape the way you write a report, accept correction, or protect a customer? Identify a concrete action and a possible conflict of interest.
Explore five proposed workforce training syllabi (96 planned clock hours), learning objectives, supervised practical exercises and college evaluation pathways. All materials are draft and are not accredited or approved for college credit.
Explore the institutional course catalog →MRR University is not affiliated with or endorsed by Grand Rapids Community College.
Understand how your RV works, identify warning signs, and know when to call a qualified technician.
Take the free starter lesson ↗Explore structured pathways in electrical, plumbing, appliances, roof systems, diagnostics and safety.
Explore the curriculum ↗Planned advanced education in diagnostic workflows, service documentation, fabrication and operations.
Register your interest ↗Fourteen proposed subject areas support the detailed course catalog and lesson outlines below. These are planning descriptions, not state-approved courses.
Construction, major systems, inspection routines and service terminology.
Curriculum in planningGet notified about courses →Battery banks, fuses, converters and safe fault isolation.
Curriculum in planningGet notified about courses →Shore power, breakers, GFCIs and safe diagnostic boundaries.
Curriculum in planningGet notified about courses →Fresh water, pumps, water heaters, waste tanks and leak diagnosis.
Curriculum in planningGet notified about courses →Furnaces, rooftop air conditioning and ventilation fundamentals.
Curriculum in planningGet notified about courses →Refrigerators, controls, operating conditions and service basics.
Curriculum in planningGet notified about courses →Inspection, moisture intrusion, sealants and exterior assemblies.
Curriculum in planningGet notified about courses →Drive types, maintenance, alignment principles and troubleshooting.
Curriculum in planningGet notified about courses →Component identification, hazard recognition and qualified-service protocols.
Curriculum in planningGet notified about courses →Charging, inverters, solar controllers and power planning.
Curriculum in planningGet notified about courses →Running gear inspections, bearings, brakes and service safety.
Curriculum in planningGet notified about courses →Fitment, materials, non-structural fabrication and design.
Curriculum in planningGet notified about courses →Cabinetry, upholstery, pop-ups and repair versus replacement.
Curriculum in planningGet notified about courses →Estimates, documentation, customer communication and workflow.
Curriculum in planningGet notified about courses →Four proposed learning pathways organize 14 RV subjects. Listed clock hours are initial curriculum-development estimates, not approved hours or an advertised enrollment schedule.
Learn to recognize problems, document inspections, and make safe decisions about professional repair.
Proposed sequence: RV-101 · RV-130 · RV-160 · RV-180
See detailed course outlines ↓Build systems literacy, troubleshooting documentation, and practical observation skills before specialized technician training.
Proposed sequence: RV-101 · RV-110 · RV-120 · RV-130 · RV-140 · RV-150 · RV-170 · RV-180 · RV-200
See detailed course outlines ↓Plan nonstructural parts, custom interiors, preventive exterior care, and restoration work.
Proposed sequence: RV-160 · RV-170 · RV-190 · RV-210 · RV-220
See detailed course outlines ↓Understand service workflows, work orders, estimates, customer authorization, and quality assurance.
Proposed sequence: RV-101 · RV-230
See detailed course outlines ↓| Code | Course | Category | Estimated hours | Outline |
|---|---|---|---|---|
| RV-101 | RV Fundamentals | Foundations | 8 h | View syllabus |
| RV-110 | 12V DC Electrical | Electrical | 14 h | View syllabus |
| RV-120 | 120V AC Electrical | Electrical | 14 h | View syllabus |
| RV-130 | Plumbing & Water Systems | Water systems | 12 h | View syllabus |
| RV-140 | Heating, Ventilation & AC | Climate | 14 h | View syllabus |
| RV-150 | RV Refrigeration & Appliances | Appliances | 12 h | View syllabus |
| RV-160 | Roofing & Exterior Sealing | Exterior | 8 h | View syllabus |
| RV-170 | Slide-Outs & Awnings | Mechanisms | 12 h | View syllabus |
| RV-180 | Propane Systems & Safety | Safety | 8 h | View syllabus |
| RV-190 | Solar, Batteries & Off-Grid | Electrical | 12 h | View syllabus |
| RV-200 | Chassis, Bearings & Brakes | Running gear | 12 h | View syllabus |
| RV-210 | Custom Fabrication & 3D Printing | Fabrication | 12 h | View syllabus |
| RV-220 | Vintage RV Restoration | Restoration | 12 h | View syllabus |
| RV-230 | RV Service Business Operations | Business | 8 h | View syllabus |
Open any syllabus to see its proposed lesson breakdown, estimated clock hours, instructional method, observable outcomes and practical evidence. Course outlines are independently developed MRR planning materials; they are not RVTI material.
Instructor-led RV walkaround and a completed inspection report.
Identify ten components and complete a visual-only inspection checklist.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | RV assemblies, construction types and terminology | Guided concepts | 2 h |
| 2 | Systems map: power, water, propane and body | Demonstration and case review | 2 h |
| 3 | Walkaround inspection and owner handoff | Supervised activity and evidence | 4 h |
| Total planned clock hours | 8 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Demonstrate meter setup and measure an isolated training board.
Trace a simulated 12V fault on a low-voltage trainer with instructor oversight.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Voltage, current, polarity and DC distribution | Guided concepts | 3 h |
| 2 | Battery, fuse, converter and charger identification | Demonstration and case review | 4 h |
| 3 | Meter reading and a documented fault-isolation workflow | Supervised activity and evidence | 7 h |
| Total planned clock hours | 14 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Use a de-energized demonstration panel to explain major AC components.
Complete a no-live-work AC hazard recognition exercise.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Shore power, outlets, breakers and GFCI identification | Guided concepts | 3 h |
| 2 | Grounding concepts and hazard recognition | Demonstration and case review | 4 h |
| 3 | De-energized inspection and escalation decisions | Supervised activity and evidence | 7 h |
| Total planned clock hours | 14 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Trace water flow through an isolated training rig.
Document a simulated water leak and suggest safe next checks.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Fresh-water routing, pump and pressure components | Guided concepts | 3 h |
| 2 | Water heaters and winterization basics | Demonstration and case review | 4 h |
| 3 | Leak symptom mapping and service documentation | Supervised activity and evidence | 5 h |
| Total planned clock hours | 12 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Observe an instructor-controlled HVAC training unit.
Prepare a diagnostic intake report from a simulated HVAC service call.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Furnace and rooftop air-conditioner component overview | Guided concepts | 3 h |
| 2 | Airflow, thermostat and control fundamentals | Demonstration and case review | 4 h |
| 3 | Symptom triage and safe referral thresholds | Supervised activity and evidence | 7 h |
| Total planned clock hours | 14 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Compare appliance labels, airflow paths and sample fault reports.
Identify appliance type and complete a visual-condition report.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Absorption versus compressor refrigeration | Guided concepts | 3 h |
| 2 | Operating conditions and airflow principles | Demonstration and case review | 4 h |
| 3 | Owner-level checks and qualified-service referrals | Supervised activity and evidence | 5 h |
| Total planned clock hours | 12 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Inspect sample membrane and sealant condition boards.
Record mock roof defects using a standardized photo checklist.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Common roof membranes and sealant categories | Guided concepts | 2 h |
| 2 | Visual moisture intrusion assessment | Demonstration and case review | 2 h |
| 3 | Inspection reporting and preventive-care schedule | Supervised activity and evidence | 4 h |
| Total planned clock hours | 8 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Review a stationary mechanism model and diagram its components.
Assess a de-energized mock-up for observable maintenance concerns.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Common slide drive and awning mechanisms | Guided concepts | 3 h |
| 2 | Mechanical pinch points and lockout principles | Demonstration and case review | 4 h |
| 3 | Inspection notes and service referral criteria | Supervised activity and evidence | 5 h |
| Total planned clock hours | 12 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Instructor demonstrates hazard recognition using non-pressurized props.
Complete a scenario-based stop-work and emergency-response evaluation.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Containers, regulators and appliance identification | Guided concepts | 2 h |
| 2 | Leak alarms, ventilation and emergency response | Demonstration and case review | 2 h |
| 3 | Scope of work, documentation and licensed-service escalation | Supervised activity and evidence | 4 h |
| Total planned clock hours | 8 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Review a demonstration solar charging schematic without live high-energy work.
Create a basic load worksheet and identify isolation points on a diagram.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Solar panels, charge controllers and batteries | Guided concepts | 3 h |
| 2 | Loads, charging and energy-budget fundamentals | Demonstration and case review | 4 h |
| 3 | Battery chemistry hazards and system documentation | Supervised activity and evidence | 5 h |
| Total planned clock hours | 12 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Identify components on a stationary training assembly.
Complete an inspection report for simulated bearing/brake concerns.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Axle, wheel, tire and brake identification | Guided concepts | 3 h |
| 2 | Inspection indicators and safe support considerations | Demonstration and case review | 4 h |
| 3 | Inspection records, torque-spec documentation and referrals | Supervised activity and evidence | 5 h |
| Total planned clock hours | 12 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Measure and prototype a non-load-bearing cabinet clip.
Document dimensions, material choice and limitations for a sample part.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Material and load-path recognition | Guided concepts | 3 h |
| 2 | Measurements, CAD/fitment and prototype planning | Demonstration and case review | 4 h |
| 3 | Nonstructural component evaluation and quality checks | Supervised activity and evidence | 5 h |
| Total planned clock hours | 12 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Review a pop-up camper restoration case study and material samples.
Produce a written restoration scope for a mock client.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Vintage construction, moisture damage and condition mapping | Guided concepts | 3 h |
| 2 | Cabinetry, upholstery and soft-goods planning | Demonstration and case review | 4 h |
| 3 | Scope estimates and preservation versus replacement | Supervised activity and evidence | 5 h |
| Total planned clock hours | 12 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Instructor models estimate-to-invoice service workflow.
Complete a mock estimate and customer handoff checklist.
| Lesson | Subject | Method | Hours |
|---|---|---|---|
| 1 | Service intake, estimates and customer consent | Guided concepts | 2 h |
| 2 | Work orders, repair photos and communication | Demonstration and case review | 2 h |
| 3 | Quality checks, warranty notes and record practices | Supervised activity and evidence | 4 h |
| Total planned clock hours | 8 h | ||
Hours are planning estimates, not approved training hours, RVTI credits or college credit. Written quizzes and practical evaluations on this page are demonstrations only.
Each course needs an assigned instructor whose relevant education or field experience and applicable licenses/certifications can be evaluated. No named faculty are listed or claimed as hired. The template below can be completed before formal regulatory review.
Full name, assigned subject, work history, teaching experience, relevant education and resume/CV reference.
Certification name, issuing organization, credential validity, applicable licensing requirements and verification date.
Course assignment, assessor eligibility, training review dates and skill-assessment signoff.
| Name | Subject | Evidence review | Action |
|---|---|---|---|
| No instructor records entered. No instructors are verified or assigned. | |||
Entries exist only in memory and disappear when this page closes or reloads. Export a draft before leaving.
These four short quizzes are introductory review only. For the proposed college-sophomore-level MRR-RV205 course, use the analytical weekly modules and applied assessment exemplars above; these basic checks are not a substitute for the advanced midterm or final.
Practice scores are not saved to student records, do not count as RVTI exams and do not create a certificate or professional license. You may retake exams for study.
Review evidence-based checklists for supervised RV training activities. Safety-critical criteria are explicitly marked. Use a qualified assessor and an appropriate controlled environment. A completed worksheet is not an industry certification.
| Criterion | Observed result |
|---|
We intend to explore recognized industry training pathways and applicable school licensing before offering paid vocational programs. A certificate of participation is not the same as an industry certification, state authorization, or institutional accreditation.
Free introductory materials and general education, clearly distinguished from paid training.
Try written knowledge checks and review supervised practical rubrics below. Scores are educational only; no credits, awards or qualifications are issued.
Any future RVTI-related credentials would be offered only with the requisite authorization and approvals.
Tell us which subjects you want to study. Your message goes to Michigan RV Repair; it does not create an account, reserve a seat, or charge tuition.
Questions?
service@michigan-rv-repair.com
616-290-3592
Form delivery uses FormSubmit and requires activation/testing on the receiving email account before publishing.
A 15-week, proposed 5-credit second-year technical course: 75 planned contact hours, 150 independent-study hours, 15 advanced problem-and-case units, supervised lab plans, and an integrated diagnostic capstone. Not accredited, state-approved, RVTI-authorized, or GRCC credit-bearing.
Explore the semester course →